C8000
sync interface
C8840
digital audio
modular
processing system
7/8
PARAMETERS
Connect a clock source with SYNC A IN and an other one with SYNC B IN
The dedicated LOCK A LED turns from red to green to indicate that this input is in use right now and
the C8000 system timing is locked to that source. The LOCK B LED slowly flashes green to indicate
that the input is locked to that reference but it is not in use for the C8000 system clock :
SYSTEM CLOCK selection of the C8000 system clock
Sample Rate (kHz) [44.1, 48, 88.2, 96 FOLLOW]
Allow 96kHz [ON, OFF]
Fallback Sample Rate (kHz) [44.1, 48, 88.2, 96]
Fallback Video Rate (fps) [25, 29,97, 30]
Sync Source Priority
Sync A [ON, OFF]
Sync B [ON, OFF]
Sync Internal [ON, OFF]
Fallback on Sync Error Internal
Video Sync Shift
Video Sync [-1023 … 0 … 1023]
Shift Offset (lines)
Kommentare zu diesen Handbüchern